Flue relining
Sweep & inspection
Caps & crowns
Masonry repair
Gas fireplace serviceLevel 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Gelco Flue Liner Replacement: The Houston Owner’s Guide
We stock and install Gelco-compatible flue liner replacement in Houston, with most complete liner swaps running between $1,800 and $3,400 depending on the liner length, diameter, and what we find once the old liner comes out. If you call before noon on a weekday, we can usually get a technician to your home within 48 hours to measure and confirm the right Gelco spec for your fireplace or furnace. The way most Houston homeowners discover their Gelco liner has failed is not dramatic: a chimney inspection flags it, or they notice flaking tile pieces in the firebox, or a musty smell drifts into the living room after a rain.
Gelco built a reputation for stainless steel and aluminum chimney liners that hold up in places with real weather, and Houston’s humidity plus the temperature swings between August and January put a liner through more than the manufacturer’s idealized test conditions. But here’s the honest part: most Gelco liners do not fail suddenly. They thin, pit, or pull apart at a seam over years, and the failure only becomes visible when moisture or exhaust starts behaving strangely. Our job is to tell you exactly what you have, exactly what the replacement involves, and exactly what it costs before any work begins.
Key Takeaways:
- We install Gelco-compatible stainless steel liners matched to your existing model’s diameter and length, with a written price before work starts.
- Most Houston Gelco liner replacements run $1,800 to $3,400 installed, with the spread driven by liner size, roof access, and whether the old liner fights on the way out.
- Every job includes the Cedarwell Care Promise: shoe covers, drop cloths, a photo of the clean-up, and no surprises on the invoice.
- We’re an independent Houston chimney company, not affiliated with Gelco, but we stock and install their liners and we know which aftermarket equivalents are safe to use.
Which Gelco Models This Applies To
Gelco’s flue liners generally fall into a few families: the Gelco GA series (aluminum, most common in older furnace and water heater vents), the Gelco GS stainless series (the workhorse for wood-burning fireplaces and gas inserts), and the Gelco GC series (heavier-gauge stainless, spec’d for higher-temperature and mixed-fuel applications). The fastest way to identify what you have is to look for the printed label near the top of the liner where it exits the chimney, or on the manufacturer’s tag that may be attached to the appliance connector. If the label is gone, which happens after a decade of Houston heat and rain, we measure the inner diameter and check the wall thickness against Gelco’s published specs to confirm what should go back in.
The compatibility gotcha with Gelco, and the reason a generic liner is sometimes not a safe swap, is the crimped end profile. Gelco liners use a specific crimp depth and pitch where sections mate, and mixing a Gelco liner with an off-brand connector can leave a gap that leaks flue gas into the chase or attic. We carry genuine Gelco and the aftermarket equivalents we trust (DuraFlex and HeatShield lines, specifically) and we will not mix brands mid-run without telling you and sealing the transition properly. For Houston homes with older Gelco GA aluminum liners on gas appliances, we typically recommend upgrading to stainless, because aluminum corrodes faster in our coastal humidity and the price difference is often under $400 on a standard one-story flue.
Styles & brands we work with





Signs Your Gelco Flue Liner Replacement Is Failing
- Flaking tile or metal pieces in the firebox or at the base of the chimney. This usually means the liner has thinned to the point where material is spalling off, and the liner is no longer containing exhaust the way it should.
- A persistent musty or damp smell from the fireplace after rain. Water is working past the liner or through a failed joint, and in Houston’s wet season that moisture never really dries out on its own.
- Visible rust staining on the exterior brick above the roofline. Moisture plus flue gas creates acidic compounds that eat through the liner and then bleed outward through the masonry.
- Difficulty starting or keeping a fire lit, especially on humid days. A compromised liner changes the draft, and Houston’s already-heavy air makes a weak draft feel worse than it would in a drier climate.
- You hear a rattling or buzzing sound from the chimney when the wind picks up. Loose sections or separated joints catch the wind and vibrate, which tells us the liner has moved or separated somewhere along the run.
Any one of these is worth a camera inspection, which we include with every replacement quote so you can see what we see. We do not recommend running the fireplace while any of these symptoms are present, because a failed liner can route carbon monoxide into living spaces rather than up and out.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
In Houston, a complete Gelco flue liner replacement typically runs between $1,800 and $3,400 installed. The variables that move you within that range are straightforward: the height of the chimney (a two-story run costs more than a single-story run because of access and liner length), the diameter of the liner (larger-diameter liners cost more per foot), and whether we need a second technician on a steep roof or a particularly tight chase. The price is parts plus labor, and you see both line items before you approve anything.
| Scope | Typical Houston Installed Price |
|---|---|
| Single-story, standard 6-inch stainless liner, straightforward pull-out | $1,800 – $2,400 |
| Two-story or steep roof access, same liner | $2,300 – $2,900 |
| Liner plus new connector and top plate, any height | $2,500 – $3,400 |
| Camera inspection with written report (included with every replacement quote) | Included |
Every liner we install in Houston carries our 365-Day Done Right Promise: if the work isn’t right, we make it right, no fine print. We also leave your floors exactly as we found them, which for families with kids and pets means drop cloths down before the first tool comes out and a photo of the clean-up before we leave.
DIY or Call Us?
You can safely check a few things yourself: look for visible flaking or staining in the firebox, note any unusual smells after rain, and take a flashlight to the visible portion of the liner from below. What you should not do is attempt a liner replacement yourself. A flue liner runs the full height of your chimney, often through tight masonry and around offsets, and getting the old one out and a new one seated correctly requires roof access, a second person on the ground, and a working knowledge of the clearances and connections that keep flue gas out of your attic and bedrooms. If the liner comes apart mid-pull and a section drops, that is a serious injury risk to the person below.
Danny Cortes grew up in East Los Angeles and picked up his first trade skills at Los Angeles Trade-Technical College before making his way to Texas. He has spent the better part of two decades cleaning and inspecting chimneys across the Houston area, including older homes near Rice Military where masonry fireplaces tend to hide years of quiet buildup. He will tell you what he found before we touch a thing, and he will not sell you a liner replacement the camera does not show you need. Call (254) 978-7413 and we will schedule the inspection.
FAQs
A stainless Gelco GS or GC liner typically lasts 15 to 25 years in Houston, while an aluminum GA liner on a gas appliance often lasts 10 to 15 years, with our humidity and the salt content in the coastal air shaving a few years off what the manufacturer’s dry-climate estimates would suggest. Call (254) 978-7413 and we can inspect yours and tell you where it falls on that curve.
In most cases, no: once a liner has thinned, pitted, or separated, a section repair is a short-term patch that fails again, and we would rather tell you that honestly than sell you a repair that wastes your money. Some minor joint separation at the top can be re-secured, but the only way to know is a camera inspection, which we include free with every replacement estimate.
A standard single-story Houston liner swap takes one crew about four to six hours from setup to clean-up, and a two-story or difficult-access job can run a full day. We protect your floors and furniture, and the crew does not leave until the clean-up photo is taken.
We stock the most common Gelco-compatible stainless liner diameters on the truck, and we also keep DuraFlex and HeatShield equivalents for cases where a full Gelco-specific liner is not required. If a custom diameter or length is needed, we order it and typically have it within a few business days.
Written by Danny Cortes, Owner & Lead Chimney Technician, Kindling Chimney Houston at Kindling Chimney Houston, serving Houston and nearby areas.